HOME >> PRODUCTS >> Lithium Battery Production Machine Line >> Pouch Cell Machine
The equipment comprises: temperature control system, over/under-temperature alarm system, over/under-voltage alarm system, pressure control system, formation cabinet system, and fixture mechanism.
It features layer-independent temperature control, pressure regulation, charge/discharge functions, overcharge/overdischarge protection, stable tab-to-contact connection, data communication, data storage after process completion, voltage grading post-charging, capacity grading post-discharging, and smoke alarm.
3. Equipment Structure
4. Fixture Structure and Overall Dimensions (for reference)
5. Battery Placement
6. Operation Process:
Open cabinet door → Place battery → Close cabinet door → Set parameters → Fixture clamps → Start heating → Start formation → Formation completes → Fixture releases → Open cabinet door → Remove battery
7. Equipment Features
1. Compatible with cell thickness range of 3–12mm, no need to adjust fixture or replace tab blocks
2. Nickel alloy spring-type contact points, easy-to-plug contact boards, electrolyte corrosion resistant, easy to clean
|
No. |
Parameter Name |
Technical Specification |
Description |
|
1 |
Heating Method |
Fiberglass heating plate |
Independent temperature control per layer |
|
2 |
Temperature Control Method |
Independent temperature control per layer |
One-touch touchscreen setting |
|
3 |
Temperature Rise (20℃–80℃) |
15–30 Min |
Target temp: 80℃ |
|
4 |
Temperature Control Range |
Room temp – 85℃ |
Accuracy: ±2℃ |
|
5 |
Pressure Output Range |
80–180 KG |
Cylinder diameter: 200mm |
|
6 |
Cylinder Drive Method |
Left to right |
Parallel pressing |
|
7 |
Pressure Accuracy |
Top & bottom ≤±5KG |
|
|
8 |
Execution Mode |
Each fixture executes steps independently; system-wide temperature/pressure execution |
One product type per run |
|
9 |
Pressure Setting Method |
Input cell size, surface pressure, step time on touchscreen; system calculates & applies pressure |
Supports data saving and reuse |
|
10 |
Plate Spacing |
22mm |
Optimized for ease of operation |
|
11 |
Tab Contact |
Nickel alloy spring type |
No coating, easy cleaning |
|
12 |
Tab Block |
Teflon injection molded |
Flame-retardant, corrosion-resistant |
|
13 |
Number of Channels |
8 channels |
Controlled via upper computer software |
|
14 |
Voltage Output Range |
DC 20mV – 4500mV |
|
|
15 |
Voltage Accuracy |
±0.1%FS ±0.1%RD |
Resolution: 1mV |
|
16 |
Current Range |
DC 20 – 6000 mA |
|
|
17 |
Current Accuracy |
±0.1%FS ±0.1%RD |
Resolution: 1mA |
|
18 |
Steps per Cycle |
1–32 steps |
|
|
19 |
Voltage Qualification Rate |
≥99% |
Excludes non-equipment factors |
2. Applicable Product Parameters
|
|
Parameter |
Range |
|
Cell Length (A) |
20–120mm |
|
|
Cell Width (B) |
30–80mm (excluding airbag) |
|
|
Cell Thickness (H) |
3–12mm |
|
|
Tab Spacing (C) |
5–85mm |
|
|
Tab Shoulder (D) |
≤25mm |
|
|
Tab Length (E) |
≥8mm |
|
|
Polarity Direction |
Airbag side is the positive side(adjustable) |
1. Working modes: constant current charging, constant current/voltage charging, constant current discharging, rest, and cycling; cut-off conditions: voltage, time, final current, and final capacity.
2. Formation steps can resume from power failure, manual pause, software shutdown, communication failure, and abnormal stop.
3. All step curves and test data per battery are saved; current and historical data can be viewed per channel in data or curve format; Excel export supported for single/batch and auto export after completion.
4. Multiple inspection interfaces: graphical, summary data, categorized data, abnormal indicators.
5. Step protections for voltage, current, temperature, and pressure with alarm alerts.
6. Minimum PC configuration: PII/300 CPU, ≥2GB RAM, ≥250GB HDD, EGA/VGA display, mouse & keyboard, Windows 7 or above, one USB serial port, one network port.
Operation software provided; user supplies the PC.
7. Protection Functions:
(1) Over-voltage, under-voltage, over-current, under-current, over-capacity protection
8. Three-color status indicator lights:
Yellow: Standby (fixture not clamped)
Green: In process (clamped and charging)
Red: Fault (over/low temp/voltage, smoke, communication error)
1. Power Supply: AC380V, 50Hz, three-phase five-wire, voltage fluctuation ±10%
2. Power Consumption: MAX 2KW
3. Compressed Air: 0.3–0.75MPa, fluctuation ±1% (dehydrated, oil-free, filtered, stabilized clean air)
4. Equipment Specs:
l Weight: ~120KG
l Dimensions: L0.9m × W0.7m × H0.6m
l Color: Light gray or customer-specified
5. Environment:
l Temp: 0–45℃
l RH: 30%–75%RH, ensure dry, ventilated, acid/alkali-free
l Grounding: Protective grounding
|
No. |
Name |
Model |
Unit |
Qty |
|
1 |
Namecard Paper |
Customized |
Sheet |
12 |
|
2 |
Communication Cable |
3*0.3mm² Shielded |
Meter |
5 |
|
3 |
Plug |
General |
Piece |
20 |
|
4 |
Communication Module |
USB-RS485 |
Piece |
1 |
|
No. |
Name |
Spec/Model |
Unit |
Qty |
|
1 |
Air Switch |
NXBLE-63 C40 |
Unit |
1 |
|
2 |
Contactor |
CJX2-3210 |
Unit |
1 |
|
3 |
Contactor |
CJX2-2510 |
Unit |
3 |
|
4 |
Touchscreen |
TPC7012Es |
Unit |
1 |
|
5 |
Solenoid Valve |
4V220-08B |
Piece |
3 |
|
6 |
Solenoid Valve |
2V025-08B |
Piece |
6 |
|
7 |
Cylinder |
SC120 |
Unit |
1 |
|
8 |
PLC Controller |
CY-V22 |
Unit |
1 |
|
9 |
Temp. Control Module |
TP27N |
Unit |
1 |
|
10 |
Load Sensor |
0–3T |
Piece |
1 |
|
11 |
Power Supply |
LRS-200-24 |
Unit |
1 |
|
12 |
Constant Current Source |
Neware 5V2A-16 |
Unit |
1 |
Contact: Lily You
Phone: +86 18650702009
Tel: +86 18650702009
Email: saleskatbattery@gmail.com